VES AIR HANDLING UNITS
part of a complete range of innovative
flexible products from the HVAC experts
HIGH EFFICIENCY
HEAT RECOVERY
low energy fans
fitted controls with
touch screen remote
wide range of models
for ceiling void, plantroom
and outdoor location
L2 compliant classroom unit
All units suitable for demand
ventilation using a VES air
quality sensor
Page view 0
1 2 3 4 5 6 ... 23 24

Summary of Contents

Page 1 - HEAT RECOVERY

VES AIR HANDLING UNITS part of a complete range of innovativeflexible products from the HVAC expertsHIGH EFFICIENCY HEAT RECOVERYlow energy fansfitted

Page 2

HEAT RECOVERY AIR HANDLING UNITS10Sizes 7,8&9Design Detailsf50mm double skinned case certified to EN 1886 standard.fDirect drive centrifugal plug

Page 3 - One range ... many options

SelectionCurves11ECO NRG 7ECO NRG 8ECO NRG 9

Page 4

HEAT RECOVERY AIR HANDLING UNITS12SpecificFan Power(SFP)Watts/litre/second per fanfAs required in Building Regulations, Part L2A, Section 10, Equation

Page 5 - AQ Sensor Features

13Air Volume 400 volt 3 phase m3/sec 30Hz 35Hz 40Hz 45Hz 50Hz 55Hz 60Hz 65Hz 70Hz 75Hz 80Hz0.30 0.62 0.83 1.04 1.37 1.71 2.050

Page 6 - Sizes 0, 1&2

DIMENSIONSfTop or bottom access.fUnit can be handed in oneof two configurations.fHorizontal mounting.fFitted hot water or electricheater.fIsolators fi

Page 7 - 1&2

Sizes0,1&2WeatherproofUnitsfFlat horizontal units with topaccess.fUnit can be handed in oneof two configurations.fFitted hot water or electricheat

Page 8 - Sizes 3,4

DIMENSIONSfFlanged connections20mm Mez.fHandings may be leftor right hand side.fOptional controlsfitted on supply side.fSilencers can be fitteddirect

Page 9

fHandings may be leftor right hand sidefOptional controlsfitted on supply side.fFlanged connections20mm MezfSilencers can be fitteddirect to unit.Size

Page 10 - Sizes 7,8&9

DIMENSIONSfSide access to filters, fans, dampermotor.fHandings may be left or right hand side.fInverters fitted inside of the unit with akeypad on the

Page 11 - Selection

Sizes 7,8& 9WeatherproofUnitsNote access requirements to side of unit for maintenance:Size 7 - 850mmSize 8 - 900mmSize 9 - 1000mmUnit Size A B C D

Page 12 - Fan Power

2Contents:Options and features 3-4Controls 4-5Size 0, 1 & 2 details 6-7Size 3, 4, 5 & 6 details 8-9Size 7, 8 & 9 details 10-11Specific fan

Page 13

SilencersHEAT RECOVERY AIR HANDLING UNITSfAll silencers designed to fit directly to Ecovent NRG unit if required.Selection Curve - ECO NRG P Size 0, 1

Page 14 - Sizes 0,1&2

SilencersSilencer attenuation - Insertion Loss - dBEco NRG Silencer Centre Frequency Hz Model Model 63 125 250 500 1k 2k 4k 8k3 N

Page 15 - 0,1&2

HEAT RECOVERY AIR HANDLING UNITS22Hot WaterHeaterBatteriesPerformance DatafBased on EAT -5°C.fLow pressure hot water LPHW 82 / 71°C.fVES Sales Departm

Page 16 - 3,4,5& 6

23fWith a plate heat exchanger there is no cross-contamination of airflow, soit is possible to extract air from contaminated sources, and incorporate

Page 17

HEAT RECOVERY AIR HANDLING UNITSfThe centrifugal plug fans have infiniteadjustment and control by inverter, with realenergy savings as the speed is re

Page 18 - 7,8& 9

3Size 7, 8 & 9 key features:• Air volume up to 2.5m3/sec• 50mm cases constructed to EN1886 standard, including low airleakage to rating L3• Cases

Page 19

- All Ecovent NRG units contain a cross flow plate heat exchanger which has nocross contamination of moisture, smells or fumes. - All units have a fi

Page 20 - Silencers

Control FunctionsfIntelligent start up – the unit monitors thestart up time over a period of time andautomatically adjusts start time each day tomeet

Page 21

HEAT RECOVERY AIR HANDLING UNITS6ECO NRG PSizes 0, 1&2 fCompact construction, with 15mm doubleskinned case and Class O ratedthermal/acoustic infil

Page 22 - Batteries

SelectionCurvesSizes 0,1&2 7ECO NRG P 1ECO NRG P 2ECO NRG P 0SFPWatts/litre/secSFPWatts/litre/secSFPWatts/litre/secVoltsVoltsVolts

Page 23 - Stacked Configuration

HEAT RECOVERY AIR HANDLING UNITS8Sizes 3,4,5&6f25mm double skinned cases,available plantroom orweatherproof, flat or stackedconfiguration. All uni

Page 24 - Sizes 7, 8 and 9

SelectionCurves4504003503002502001501005000 0.1 0.2 0.3 0.4 0.5 0.